ВУЗ: Не указан

Категория: Не указан

Дисциплина: Не указана

Добавлен: 28.09.2024

Просмотров: 711

Скачиваний: 0

ВНИМАНИЕ! Если данный файл нарушает Ваши авторские права, то обязательно сообщите нам.

4 - Sequencer

Sequence Clock

The Tempo and Meter screen are not accessible when Tempo Track is selected.

O The Arpeggiator and Sequencer use the SAME CLOCK.

Change the Arpeggiator clock to adjust the tempo of Flash sequences …

…or Copy the Flash sequence to RAM, then adjust the tempo.

Clock Source. Determines if the sequencer clock is controlled by the internal or and external (MIDI) clock.

Tempo Control. Allows the tempo of a sequence to be controlled in one of three ways:

a.By the Tempo Track stored in the sequence. An initial tempo value is stored when you create a new sequence. Sequences imported from an external sequencer may have tempo changes within the song.

b.By the adjustable Screen Value tempo value shown in this display.

c.By an External Clock (MIDI).

Tempo. Sets the tempo (speed) of the sequence and is adjustable from 20 beats per minute (bpm) to 240 bpm.

Meter. Sets the time signature of the song. The Meter setting is used by the metronome function to determine measures and beats.

MIDI Clock Out. Turns MIDI Clock Out on or off. Turn this feature on if you want to control an external MIDI device with the sequencer clock.

v To Set the Clock:

1.From the main sequencer screen, press the Edit function key (F3).

2.Press the Setup function key (F3). A row of function keys appears.

3.Press the Clock function key (F2).

4.Select the Clock Source as internal or external clock.

5.Set the Tempo Control to Tempo Track, Screen Value or External Clock.

6.Set the desired Tempo (if Screen Value is selected)

7.Set the desired Meter (if Screen Value is selected). Any time signature can be programmed.

8.Turn MIDI Clock Out On or Off.

9.Press Exit to lock in the Clock settings and return to the Sequence Edit screen.

EOS 4.0 Software Manual 163


4 - Sequencer

Sequence Input

Sequence Input

This screen allows you to quantize and add swing to a sequence as it is recorded. This is particularly useful when recording drum parts. When you know you want a track to be quantized this is the fastest and easiest way to do it.

O A small “Q” symbol

 

 

 

It is important to set up the Metronome and Meter when using quanti-

appears in the Edit screen to

zation. The sequencer quantizes to the Metronome beat and the

remind you that Input Quantize

Metronome beat is controlled by the Meter setting.

is turned On.

 

 

 

 

Quantize Input. Turns Input Quantization On (yes) or Off (no).

 

Amount. Sets the note value for quantization if Quantize is turned on.

 

Data input to the sequencer can be quantized to: 1/4, 1/4 triplet, 1/8, 1/8

 

triplet, 1/16, 1/16 triplet, 1/32, 1/32 triplet, 1/64 or 1/64 triplet.

OSee Quantize in the Swing. Sets the swing value if Quantize is turned on. A value of 50% equals

Tools section for diagrams

no swing. Normal swing values range from 50% - 80%.

illustrating how Quantize and

 

 

Swing work.

v To Set the Input Functions:

 

1.

From the main sequencer screen, press the Edit function key (F3).

 

2.

Press the Setup function key (F3). A second row of function keys

 

 

appears.

 

3.

Press the Input function key (F3). The screen shown above appears.

 

4.

Turn input Quantize On or Off (Yes or No).

 

5.

Set the Quantization Amount.

 

6.

Select the Swing percentage if desired (50% = No Swing).

 

7.

Press Exit to lock in the Sequence Input settings and return to the

 

 

Sequence Edit screen.

164 E-MU Systems



4 - Sequencer

Sequence Record

Sequence Record

These two functions determine when sequence recording begins.

Start Record -

Button Press: Recording begins as soon as you press the Record and Play buttons and after the selected Count In beats (see below) have elapsed.

First Note: Recording begins as soon as you press any note on the keyboard. The Count In beat setting is ignored.

The Count In field is not Count In

available unless Button Press is Sets the number to metronome beats which will occur before actual selected. recording will commence. The number of count In beats can be set from 1

to 127 or turned Off.

v To Set the Sequence Record Functions:

1.From the main sequencer screen, press the Edit function key (F3).

2.Press the Setup function key (F3). A second row of function keys appears.

3.Press the Record function key (F4). The screen shown above appears.

4.Set Start Record for Button Press or First Note.

5.Set the number of Count In beats.

6.Press Exit to lock in the Sequence Record options and return to the Sequence Edit screen.

EOS 4.0 Software Manual 165


4 - Sequencer

Sequence Loop

_ Loop settings are NOT saved with the sequence.

Sequence Loop

Any region of a sequence can be programmed to loop. The sequence plays through the Start Time until the selected End Time is reached. It will then immediately jump back to the Start Time and the sequence will continue to play between the selected Start and End times.

Loop Region. Turns looping on or off.

Start/End Time. Selects the Start and End times for the looping region in bars:beats:ticks.

Start Time

End Time

Loop

Play

 

v To Set the Sequence Loop:

1.From the Sequencer Manage screen, press the Edit function key (F3).

2.Press the Setup function key (F3). A second set of function keys appears.

3.Press the Loop function key (F5). The screen shown above appears.

4.Turn Loop Region On or Off.

5.Select the Start and End time in bars/beats/ticks using the cursor keys to select the field and the Data Entry Control or INC/DEC keys to change the selection. The start time will default to the current sequence position.

Press the All Time function key to select everything in the selected track(s).

6.Press Set to set the Loop Region or Cancel to cancel the operation.

166 E-MU Systems