USING EXPRESSION PEDALS & FOOTSWITCHES

Pedals & MIDI

An expression pedal connected to the “Input 2 ( pedal )” jack transmits MIDI CC 2 ( also known as breath control ).

NOTE:

In Performance Mode, MIDI messages will only transmitted if at least one Part has the “Expression pedal” on page 3 of the Part edit Midi menu set to “On”.

What the Pedal does in Program mode

An expression pedal connected to the “Input 2 ( pedal )” jack generates breath control data which can then be re-mapped according to the setting of the “Breath control” parameter on page 4 of the Global menu.

Page 4 looks like so:

MIDI clock

Int

Pedal/breath

Off

For example, if the “Breath control” parameter in the Global menu was set to “MW”, all data generated by the pedal would be passed on to the currently selected Program as if it were modulation wheel data ( CC 1 ) taking into account all of the Wheel settings in the Program’s modulation matrices.

What the Pedal does in Performance mode

In Performance Mode, each individual Part has its own settings which determine whether it transmits Pedal data & how the Part responds to any MIDI data generated by a Pedal ( both when received directly from the pedal or played back later from a sequencer ). These parameters are accessed on pages 3 & 4 in the Part edit Midi menu.

Page 3 looks like so:

Expression pedal

Off

The “Pedal/breath” parameter on page 3 of the Midi menu determines whether the Part will respond to breath/pedal MIDI messages ( CC 2 ). These messages could be generated directly by an expression pedal connected to the “Input ( pedal )” jack or received from a sequencer via MIDI In. When this parameter is set to “On”, the breath control data which is then re-mapped according to the setting of the “Breath control” parameter on page 4 of the Global menu. For example, if this parameter in the Global menu was set to “MW”, all data generated by the pedal would be passed on to the Part as if it were modulation wheel data ( CC 1 ) taking into account all of the Wheel settings in the Parts Program’s modulation matrices.

109

TROUBLESHOOTING

Footswitch does not appear to work when connected to the “Input 2 ( pedal ) socket.

Make sure the Input 2 ( pedal ) socket is not set to “Off” on page 9 of the Global menu.

Make sure the Input 2 ( pedal ) socket is not configured for “Pedal-T” or “Pedal-R” on page 9 of the Global menu.

Pedal / footswitch works fine in Program Mode but does not appear to work in Performance Mode.

Make sure Part is enabled ( its Polyphony setting is not set to “Off” ). Make sure the jack socket is set to “On” for the Part ( page 3 in the Part edit Midi menu ).

Pedal / footswitch works, but behaves in the opposite manner to the way expected.

Switch to the opposite type of pedal / footswitch configuration ( page 9 in the Global menu ).

No Power.

Power Supply not connected properly. If applicable, check fuse in mains plug.

No Sound.

Check the“Volume” knob is not set at zero. Check that the correct MIDI receive Channel is selected. Check that all mixer parameters are not set to zero. Check that a Volume MIDI Message of zero is not being transmitted to Nova. Check that the Filter Frequency knob or Sustain & Decay knobs of Env1 are not set to zero. Check that Local On/Off in Global Mode is not set to Off. Check Arp Mute is not active. ( lit ) Check Part Polyphony is not set to Off. Check Pass to Effects parameter in Dist/EQ/Config menu is not set to Input 1 or 2 but program. Check that the Arpeggio notes to: parameter in Arp Menu is not set to MIDI only. Check Part levels in a Performance are not set to 0. Another possibility is that the Program being monitored is an Arpeggiated one & the MIDI clock parameter in the Global menu is set to external and there is no MIDI clock being received.

LFOs, Delays and/or Arpeggiator do not sync to MIDI Clock.

Check the Clock parameter in the Global Mode is set to Ext. ( refer page 38 ) If this is set to external, check the Nova is synced by varying the tempo of the Sequencer. If the Nova speeds up & slows down accordingly, the Nova is synced to MIDI Clock. However it is possible to synchronise the LFOs, Delay & Arpeggiator to many different time signatures. This can lead to a situation where the Nova may be synced but synchronised at a strange time signature. Check the synchronisation parameters refer to page 77 for the LFOs, page 84 for the Delay & page 50 for the Arpeggiator for details.

LFOs, Delay and/or Arpeggiator is stuck/stopped/does not work.

This is almost certainly because the LFOs, Delay and/or Arpeggiator are set to sync to MIDI Clock. To check this see if the Clock parameter in the Global Mode is set to Ext. ( refer page 38 ) If it is set to External then setting this parameter to internal will restore the operation of the LFOs, Delay & or Arpeggiator. If you wish these to be synced to MIDI Clock, leave this parameter in External & confirm that the sequencer is actually sending MIDI Clock. A lot of software sequencers default to NOT transmitting MIDI Clock. If the LFO / Delay / Arp is stuck / not functioning & you have the Clock parameter in the Global Mode is set to Ext, the sequencer is not sending MIDI Clock. There is no other reason.

Cannot record knob movements on the sequencer.

Some sequencers / software feature a “filter” for filtering out unwanted data. Controllers is usually an option. This data must not be filtered out by the program. Consult the sequencer / software's owners manual for details.

Cannot change “Banks” via MIDI.

Bank changes are different from program changes & are actually two messages. For this reason, some sequencers / software have a “Bank Box” or similar in an attempt to simplify things. However sometimes on early versions of software this function may not be available. If this is the case & your sequencer does not have a “Bank Box” or similar you will have to enter in the data manually in a “List Edit” or similar function within the sequencer. You will have to enter a controller with specific values & then a program change message, all with the right values & in the right order & on the right channels. If the message you send does not change the bank on the Nova then you are not sending the right messages & values. Consult your sequencer / software owners manual for details. Bank change messages are as follows. They must be sent as shown & in the correct order. A Program Bank “A”

110


TROUBLESHOOTING

message is as follows: enter a controller 32 message with a value of 5 followed by a program change message with the value of the program you want. i.e. for program 6 enter 7. A Program Bank “B”message is as follows: enter a controller 32 with a value of 6 followed by a program change message with the value of the program you want. Alternatively simply select the desired Performance / Program from the Nova’s front panel while recording into a sequencer. Make sure the MIDI output of the Nova is connected to the MIDI input of your sequencer / computer either directly or via a merge box.

NOTE:

There is a Table of Bank messages recognised by the Nova on page 130.

Nova does not respond to MIDI Program Change / Bank select messages.

Check that the Incoming Program change parameter in the Global mode is set to Enabled &/or the Prog change filt parameter in MIDI menu of the Part edit section is not On.

Nova does not respond to Controller messages.

Check that the Incoming control change parameter in the Global mode is set to Enabled &/or the Controller filt parameter in the MIDI menu of the Part edit section is not On.

The knobs & buttons do not alter the sound / do anything.

Check that the Local On/Off parameter in Global mode is not set to Off.

Cannot receive Sysex dumps ( Progs-Perfs )

Check that Memory Protect is set to Off & Sysex reception is set to Normal ( RX as sent ). If you are sending B bank Perfs or C/D Bank Progs from a Supernova to the Nova, then these sounds will not go into the Nova as corresponding banks do not exist in the Nova. You can however specify All Progs to bank A or B & All Perfs to bank A to get around this.

Only the signals from outputs 1&2 appear on outputs 5&6.

This is because the “Headphones out” parameter on page 9 of the Global mode is set to 1&2 ( refer page 40 for details ). This is the default setting so that outputs 5&6 can be used as Headphones that monitor the master 1&2 outputs. Simply reassign the parameter to 5&6 & these out puts will behave as outputs 5&6 & no longer monitor as headphones would.

The Nova switches itself from Perf mode to Prog mode.

This is because the MIDI out & MIDI in of the Nova is connected to a sequencer which is remapping Bank/Program messages

( generated by changing Program/Bank on a Part ) to a channel corresponding to the Global channel of the Nova. The solution is to Filter out Bank messages in the Sequencer, or disconnect the midi out of the Nova, or disable the “Thru” function on the sequencer, or to change the Global channel of the Nova to one not being used in the sequencer.

When editing a Part in Perf mode, other parts are being edited as well.

This is because the MIDI out & MIDI in of the Nova is connected to a sequencer which is remapping controller messages ( generated by editing parameters on a Part ) to a channel corresponding to the channel of the other Part. The solution is to switch the local control parameter in global to off. This means all edits will be carried out via the MIDI chain rather than directly & the sequencer will dictate which part is being edited by the MIDI channel setting on the track. The alternatives are not very friendly, they are to filter out controller messages in the Sequencer, or disconnect the midi out of the Nova, or disable the “Thru” function on the sequencer.

111

COMPATIBILITY WITH OTHER NOVATION PRODUCTS

Data compatibility with SN II series

Limited provision has been made for the Nova Laptop to load system exclusive dumps from a Supernova II Keyboard, Nova II Keyboard or Supernova II Rack.

However, it will not be possible to take across all of the parameters into the Nova Laptop. Certain features such as FM algorithms, extended envelope parameters and extended effects parameters are unique to the 2nd generation series and cannot be taken across. These features will be ignored if taken across via Sysex.

Other features such as special filter width and unison are common to both series, but are available in a reduced form on the Nova Laptop. In such cases, the settings will be approximated as closely as possible when taken across via Sysex.

New features common with 2nd generation series (can be taken across) :

Osc special waveform : Double saw

Filter special types (all)

Unison on/off

Unison voices

Special filter width modulation

Pan effects

Constant gate

Global prog change tx option

Global controllers tx option

Global finder demo switch

Global knob mode

NOTE:

The Pan effects, Special Filter width & VCO Drift parameters can only be transferred successfully if the transmitting Supernova II or Nova II has the forthcoming OS 2 or above installed.

New features common with 2nd generation series in limited form (can be taken across) :

Unison detune (default unison detune value applied when Unison is on)

Special filter width (rounded to nearest pre-set value)

VCO drift (converted to DCO/VCO mode)

Arp gate time (rounded to nearest pre-set value)

112


COMPATIBILITY WITH OTHER NOVATION PRODUCTS

Features unique to 2nd generation series (cannot be taken across) :

FM configurations

Envelope level tracking

Envelope level note

Envelope A-D repeat

Envelope sustain rate

Envelope sustain time

Oscs start phase

Arp output channel

Filter overdrive curve

Oscs filter bypass

Effects bypass

Comb filter speed

Comb filter depth

Comb filter spread

Comb filter freq wheel

Comb filter boost wheel

Distortion output level

Distortion gain compensate

Distortion curve

Chorus delay

Chorus LFO wave

Chorus speed 2

Chorus inertia

Chorus stereo width

Chorus type : Ensemble

Chorus type : Rotary speaker

LFO delay fade

LFO slew amount

Drum played as

Global input/switch settings

Global aftertouch tx option

Global velocity tx option

Global arp kbd note tx option

Global sysex tx delay

Global temp display time

Arp transpose zone settings

All external part settings

Drum maps

Digital i/o card options

Squarewave pulse width compatibility

Before OS4.0, maximum or minimum setting of “width” (+63 or –64) for an oscillator set to square wave gave a 5% pulse width. For compatibility with series 2, this has changed to 0% (ie silence).

OS4.0 does not automatically adjust this.

Few programs use these extreme settings and it is unlikely that any change will be heard.

However, if upgrading to OS4.0 has made any of your programs silent or distinctly different, please check oscillators using square wave and reduce extreme settings of width by 3 or 4 counts.

113

LOADING ADDITIONAL SOUNDS

Additional sound banks are available on our web site http://www.novationuk.com. To install the new sounds follow the procedure below. This is actually very similar to upgrading the OS in your Nova.

1

-

Download the Midi file of the Sounds for the Nova.

2

-

Connect the MIDI out of the sequencer to the MIDI in of the Nova.

3

-

Turn the Memory Protect OFF ( in page 7 of the Global mode ) & make sure your Nova is set to

 

 

Global MIDI channel 1 ( page 1 of the Global mode ).

4

-

Load the Midi file into your sequencer.

5

-

Play the sequence ( The display will show the status of incoming messages ).

NOTE:

If you experience problems with this file, it is probably due to similar problems that can occur when updating the OS. Please Refer to page 115 “Upgrading the Operating System”.

114


 

 

UPGRADING THE OPERATING SYSTEM

 

 

Please follow the instructions below for details on how to upgrade you Nova’s Operating System.

1

-

Download the latest Operating System from our site.

2

-

BACK UP YOUR DATA.

 

 

Make a backup of your data to computer. By this I mean everything. Use the “Total data” setting in the Sysex

 

 

transmission parameter in global mode.

3

-

VERIFY YOUR BACKUP.

 

 

Change the name of one of the sounds & write the change in. Then reload your sounds from YOUR BACKUP

 

 

that you have just made. If the name has changed back to what it was when you made the backup, chances

 

 

are the backup is OK.

4

-

SWITCH THE NOVA OFF.

5- CONNECT MIDI OUT OF THE SEQUENCER TO MIDI IN ON THE NOVA.

6

-

LOAD THE NovaOS4n.mid FILE INTO YOUR SEQUENCER.

7

-

HOLD DOWN PART MUTE BUTTON & SWITCH THE NOVA ON WHILE STILL HOLDING IT DOWN.

The display should show:

Waiting for midi O/S

8

-

PLAY THE SEQUENCER.

If everything is OK you’ll get a display like so indicating the amount of file received.

Receiving OS 4.O

progress...1O%

Once the file has reached 100% the display will show:

OK - updating flash progress...1O%

The Nova is now updating the OS in Flash Memory.

NOTE:

Under no circumstances switch off the Nova while this procedure is happening. Doing so may result in very erratic behaviour & may lead to the Nova needing to be sent back for service! Once the Flash has been loaded the Nova will automatically reboot as normal running the new OS.

While we have taken every precaution in designing the OS to be upgraded trouble free, sometimes problems can occur. This is not solely down to us but in almost all cases rests with the sequencer/hardware used to perform the upgrade.

If an error occurs during the upgrade process the display will show:

Packet error!!

Switch off and re-try

This is an indication that an error has occurred in the download process that does not make any sense to the Nova.